Descriptions :
The CX300 is a microprocessor based timer/counter housed in a standard
15 terminal CYCL-FLEX® plug-in case
which allows easy removal for programming changes and replacement. Time
or count operation, time range, and the
type of start input switch operation are programmed with 7 miniature
rocker switches located inside the unit housing.
The front panel of the CX300 is a sealed membrane keypad which provides
excellent protection for most industrial
environments. The time or count setpoint is entered using the increment
and decrement keys for each digit position.
The SET and ENT keys provide access to the setpoint, as well as to the
front panel programmable software functions.
These programmable functions control the pulse output length, setpoint
to zero or zero to setpoint cycle progress
indication, and count input scale factor. The software programming
functions are
indicated by prompts to help the user
program these functions without the need for written instructions.
- Keypad lock function allows viewing of
setpoint, but does not allow unauthorized changes
- 4 1/2 digit (19999) liquid crystal display - .5 inch high digits
- Annunciators (right of the display) flash to indicate timing or
counting
- Two form C instantaneous contacts and two form C programmed contacts
- Five time ranges from 19.999 sec. to 199 hr.: 59 min.
- Three count rate input rate speeds are programmable with a max. count
display of 19999 - can be extended via count
input scale factor
- 24, 120, or 240 VAC operations
- Count input available for 120 volt AC or low voltage
AC/DC operations
- When programmed as timer, count input circuit serves as time
inhibit (without resetting the unit)
- Non-volatile memory data retention
Specifications :
Time/Count Ranges :
Sym. Maximum
Minimum
Count
Range
Setting
Rate
1
19999 Cts.
1 Ct. 4000/Sec.
12-50 VDC Count Input
2
19999 Cts.
1 Ct.
500/Min. AC or DC
3
19999 Cts.
1 Ct.
5000/Min. AC or DC
4
199.99 Sec. .01
Sec.
5
1999.9 Sec. .1
Sec.
6
19.999 Sec. .001 Sec.
7 199 Min.: 59
Sec. 1 Sec.
8 199 Hr.: 59
Min. 1 Min.
- Operating Voltage/Frequency : A6 - 120 VAC, 50/60 Hz
B6 - 240 VAC, 50/60 Hz
Z6 - 24 VAC, 50/60 Hz
- Time Inhibit/Count Line Terminals B & C :
CX311/CX341 - 12-50 VDC or 20-28 VAC, 50/60
Hz
CX312/CX342 - 120 VAC, 50/60 Hz or 120 VDC
- Setting Accuracy : Time: ±0.1% or 50 ms, whichever is larger
(0° to 60°C)
Count: 100%
- Repeat Accuracy : Time: ±0.1% or 35 ms, whichever is larger
(0° to 60°C)
Count: 100%
- Reset Time : 30 ms following voltage removal from simulated clutch
input
(CR1)
- Power on Response : 300 ms max. after voltage applied to terminal 11
- Operating Temperature : +32° to +140°F (0° to +60°C)
- Output Rating: Relay : 10 amp (resistive), 120 VAC
Mechanical Life : 20 million operations
Electrical Life : contingent upon controlled load
Solid
State : 1 amp, 0-264 VAC, VDC
- Vibration : Unit function is unaffected by 2.5G sinusoidal vibration
magnitude in both directions of the perpendicular
mounting axes imposed from 10 to 100 Hz
- Static Discharge : Unit function is unaffected by a constant 3600
volt peak, 60 Hz discharge applied to the grounded
front plate at a relative humidity
of less than 25%
- Approvals : UL Recognition E96337
CSA Certification LR26861