Model No. 5DGA04AS

Maker : Advance Power Solutions.

Specifications :-

Input : 90 to 250 VAC, 0.5A, 47 to 63 Hz

Output :     5.2V, 2A
                 12 V, 0.4A
              - 12 V, 0.3A



Model : APS40ES Series

Maker : Advance Power Solutions.

Universal Input AC To DC External Deskstop Adaptor, Multiple Output Switching Power Supplies 40 Watts 

Features :-

- Automatically Accommodates Universal  AC Sources
- Desktop Adaptor With IEC 320 Input Receptacle
- Designed To Meet Universal Safety Standards
- EMI / RFI Meet CISPR Pub. 22 Class B
- CE Marking Compliance

Input Specification :
- Input Voltage : Typical 90-265 VAC
- Input Connector : IEC 320 3P-AC receptacle
- Input Frequency : 47-63Hz (Consult factory for 440Hz operation)
- Inrush Current : 15A max. @ 230VAC
- Input Current : 1.0A @ 115VAC & 0.33A @ 30VAC
- Dielectric Withstand : (1*) Meets IEC 950
- EMI / RFI : Meets CISPR PUB. 22 class B
- Hold-up Time : 30mS typ. @ 115VAC, 120mS typ. @ 230VAC

Ouput Specification :
- Output Voltage : See Voltage / Current Ratings Charts Below
- Output Currents : See Voltage / Current Ratings Charts Below
- Output Connector : Optional
- Line Regulation : ±0.1% typical
- Load Regulation : (2*) ±3-5% depending on O/P cord
- Noise & Ripple : Typ. 1% peak to peak
- OVP : Built-in +5V O/P @ +6.4V ±0.4V, Option for other O/P @ 124% typ.
- Adjustability : Factory set
- Overload Protection : 105% max. power

General Specifications :
- Efficiency : Typ. 75%
- Switching Frequency : About 37- 100 KHz
- Circuit Topology : Free-running flyback circuit
- Transient Response : Output voltage returns in less than 3mS following a 50% load change
- Safety Standard : UL1950/EN60950
- Operating Temperature : 0 to 40°C
- Storage Temperature :-20 to +85°C
- Temperature Coefficient : 0.04% per °C
- Cooling : Free air convection
- Construction : Impact resistant thermo-plastic enclosure with venting slot desktop format
 
 Remarks : (1*) Dielectric Withstand : If at the cord strain relief end for 1 minute, the results are 3,000VAC-Output/Input,
                        1,500VAC - Input/GND, 500VAC - Output/GND
                 (2*) Load regulation : The exact obtainable voltage regulation depends upon the output cord selected and
                         load currents.
                        Upper data are for 6 ft.(2 meters) cord AWG #18/20 wires with PF or PD type connector.

Voltage / Current Ratings Chart.

Tripple Output.

    Model No.            Main o/p vo1#               Aux. /p V02✝                  Aux. /p VO3 $
                                Typ.    Volt.   Peak        Typ.      Volt.    Peak         Typ.    Volt.    Peak

APS40ES-30L3      5.0A   +5V     6.0A       1.2A    +12V    2.0A       0.25A   -12V    1.0A

Symbols :" #" OVP built-in. "✝" Stacked on main output. "$"Installed with Post Regulator(PR)
Remark : Peak output, less than 60 Sec., Peak current can't be drawn from all output at the same time.

Weight : 570 g ( 20.1 Oz. )



S-4 0 series

40W Single Output Switching Power Supply

Features :

Universal AC input / Full  range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 75KHz

Model : S-40-12
Output :
- DC Voltage                                : 12 V
- Rated Current                             : 3.5 A
- Current Range                            : 0 - 3.5 A
- Rated Power                              : 42 W
- Ripple & Noise (max) Note 2     : 100 m Vp-p
- Voltage Adj. Range                    : 10.8 - 13.2 V
- Voltage Tolerance Note 3          : +/- 1.0 %
- Line Regulation                          : +/- 0.5 %
- Load Regulation                         : +/- 0.5 %
- Setup, Rise Time                        : 300 ms, 50 ms/230VAC    800 ms, 50 ms/115 VAC at full load
- Hold Up Time (Typ.)                 : 70 ms/230 VAC     15 ms/115 VAC at full load

Input :
- Voltage Range                           : 85 - 264 VAC      120 - 370 VDC
- Frequency Range                       : 47 - 63 Hz
- Efficiency (Typ.)                        : 76%/ 115 VAC
- AC Current (Typ.)                     : 1.2A/115 VAC    0.6A/230 VAC
- Inrush Current (Typ.)                 : Cold Start 25A/115 VAC     50A/230 VAC
- Leakage Current                        : < 1 mA/240 VAC

Protection :
- Overload                                   : 105 - 150 % rated output power
                                                      Protection type : Hiccup mode, recovers automatically after faulty
                                                                                condition is removed
- Over Voltage                             : 13.8 - 16.2 V
                                                      Protection type : Hiccup mode, recovers automatically after faulty
                                                                                condition is removed

Environment :
- Working Humidity                      : 20 - 90 % RH non-condensing
- Working Temp.                          : -10 to +60 deg. C ( refer to output load derating curve )
- Storage Temp., Humidity            : -20 to +85 deg. C, 10 - 96 % RH
- Temp. Coefficient                       : +/- 0.03 % / deg. C ( 0 to 50 deg. C )
- Vibration                                    : 10 to 500 Hz, 2G 10 min / 1 cycle, period for 60 min, each along X,Y,Z axes

Safety & EMC ( Note 4 ) :
- Safety Standard                         : UL1012, UL60950-1, TUV EN60950-1 approved
- Withstand Voltage                     : I/P-O/P : 3 KVAC  I/P-FG : 1.5 KVAC   O/P - FG : 0.5 KVAC
- Isolation Resistance                   :  I/P - O/P, I/P-FG, O/P-FG : 100 M Ohms / 500 VDC
- EMI Conduction & Radiation    : Compliance to EN55022 (CISPR22) Class B
- Harmonic Current                      : Compliance to EN61000-3-2,-3
- EMS Immunity                          : Compliance to EN61000-4-2,3,4,5;ENV50204, EN55024, light industry
                                                     level criteria A

Others :
- MTBF                                      : 314.1K hrs min. MIL-HDBK-217F (25 deg. C )
- Dimension                                 : 129 x 98 x 38 mm ( L x W x H )
- Packing                                     : 0.44 Kg

Note :  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient
    temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a
    0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment
     must be re-confirmed that it still meets EMC directives.

S-100F series

100W Single Output Switching Power Supply

Features :

AC input range selectable by switch
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 83 KHz

Model : S-100-7.5
Output :
- DC Voltage                                : 7.5 V
- Rated Current                             : 13.5 A
- Current Range                            : 0 - 13.5 A
- Rated Power                              : 101 W
- Ripple & Noise (max) Note 2     : 125m Vp-p
- Voltage Adj. Range                    : 6.7 - 8.25 V
- Voltage Tolerance Note 3          : +/- 1.0 %
- Line Regulation                          : +/- 0.5 %
- Load Regulation                         : +/- 0.5 %
- Setup, Rise Time                        : 1000 ms, 30 ms at full load
- Hold Up Time (Typ.)                 : 20 ms at full load

Input :
-Voltage Range                           : 88 - 132 VAC/176 - 264 VAC selected by jumper or switch      
                                                     248 - 370 VDC
- Frequency Range                      : 47 - 63 Hz
- Efficiency (Typ.)                        : 78 %
- AC Current (Typ.)                     : 3.15A/115 VAC    1.5A/230 VAC
- Inrush Current (Typ.)                 : Cold Start 20A/115 VAC     40A/230 VAC
- Leakage Current                        : < 1 mA/240 VAC

Protection :
- Overload                                   : 105 - 150 % rated output power
                                                      Protection type : Hiccup mode, recovers automatically after faulty
                                                                                condition is removed
- Over Voltage                             : 8.63 - 10.13 V
                                                      Protection type : Hiccup mode, recovers automatically after faulty
                                                                                condition is removed

Environment :
- Working Humidity                      : 20 - 90 % RH non-condensing
- Working Temp.                          : -10 to +60 deg. C ( refer to output load derating curve )
- Storage Temp., Humidity            : -20 to +85 deg. C, 10 - 96 % RH
- Temp. Coefficient                       : +/- 0.03 % / deg. C ( 0 to 50 deg. C )
- Vibration                                    : 10 to 500 Hz, 2G 10 min / 1 cycle, period for 60 min, each along X,Y,Z axes

Safety & EMC ( Note 4 ) :
- Safety Standard                         : CSA60950-1 ( for 24V only ), UL1012, UL60950-1, TUV EN60950-1 CCC
                                                     GB4943 approved
- Withstand Voltage                     : I/P-O/P : 3 KVAC  I/P-FG : 1.5 KVAC   O/P - FG : 0.5 KVAC
- Isolation Resistance                   :  I/P - O/P, I/P-FG, O/P-FG : 100 M Ohms / 500 VDC / 25 deg. C / 70% RH
- EMI Conduction & Radiation    : Compliance to EN55022 (CISPR22) Class B
- Harmonic Current                      : Compliance to EN61000-3-2,-3
- EMS Immunity                          : Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level  
                                                     criteria A

Others :
- MTBF                                      : 314.9K hrs min. MIL-HDBK-217F (25 deg. C )
- Dimension                                 : 199 x 98 x 38 mm ( L x W x H )
- Packing                                     : 0.65 Kg

Note :  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient
    temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a
    0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment
    must be re-confirmed that it still meets EMC directives.

S-150 series

150 W Single Output Switching Power Supply

Features :

AC  input range selectable by switch
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 25 KHz

Model : S-150-12
Output :
- DC Voltage                                : 12 V
- Rated Current                             : 12.5 A
- Current Range                            : 0 - 12.5 A
- Rated Power                              : 150 W
- Ripple & Noise (max) Note 2     : 180 m Vp-p
- Voltage Adj. Range                    : 10.6 - 13.2 V
- Voltage Tolerance Note 3          : +/- 1.0 %
- Line Regulation                          : +/- 0.3 %
- Load Regulation                         : +/- 0.3 %
- Setup, Rise Time                        : 100 ms, 50 ms at full load
- Hold Up Time (Typ.)                 : 28 ms at full load

Input :
- Voltage Range                           : 88 - 132 VAC/176 - 264 VAC selectable by switch    248 - 370 VDC
- Frequency Range                       : 47 - 63 Hz
- Efficiency (Typ.)                        : 82 %
- AC Current (Typ.)                     : 3.2A/115 VAC    1.6A/230 VAC
- Inrush Current (Typ.)                 : Cold Start 35A
- Leakage Current                        : < 3.5 mA/240 VAC

Protection :
- Overload                                   : 105 - 150 % rated output power
                                                      Protection type : Shut down o/p voltage, re-power on to recover
- Over Voltage                             : 13.8 - 16.2 V
                                                      Protection type : Shut down o/p voltage, re-power on to recover

Environment :
- Working Humidity                      : 20 - 90 % RH non-condensing
- Working Temp.                          : -10 to +60 deg. C ( refer to output load derating curve )
- Storage Temp., Humidity            : -20 to +85 deg. C, 10 - 95 % RH
- Temp. Coefficient                       : +/- 0.03 % / deg. C ( 0 to 50 deg. C )
- Vibration                                    : 10 to 500 Hz, 2G 10 min / 1 cycle, period for 60 min, each along X,Y,Z axes

Safety & EMC ( Note 4 ) :
- Safety Standard                         : UL1012, UL60950-1, TUV EN60950-, CCC GB4943 approved
- Withstand Voltage                     : I/P-O/P : 3 KVAC  I/P-FG : 1.5 KVAC   O/P - FG : 0.5 KVAC
- Isolation Resistance                   :  I/P - O/P, I/P-FG, O/P-FG : 100 M Ohms / 500 VDC / 25 deg. C / 70 % RH
- EMI Conduction & Radiation    : Compliance to EN55022 (CISPR22) Class B
- Harmonic Current                      : Compliance to EN61000-3-2,-3
- EMS Immunity                          : Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light
                                                     industry level criteria A

Others :
- MTBF                                      : 286.7K hrs min. MIL-HDBK-217F (25 deg. C )
- Dimension                                 : 199 x 110 x 50 mm ( L x W x H )
- Packing                                     : 0.8 Kg

Note :  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient
    temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a
    0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment
     must be re-confirmed that it still meets EMC directives.
5. If the power supply is short-circuited under no load, it will recover automatically when short-circuit is removed.

S-150 series

150 W Single Output Switching Power Supply

Features :

AC  input range selectable by switch
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 25 KHz

Model : S-150-7.5
Output :
- DC Voltage                                : 7.5 V
- Rated Current                             : 20 A
- Current Range                            : 0 - 20 A
- Rated Power                              : 150 W
- Ripple & Noise (max) Note 2     : 150 m Vp-p
- Voltage Adj. Range                    : 6 - 8.3 V
- Voltage Tolerance Note 3          : +/- 1.0 %
- Line Regulation                          : +/- 0.5 %
- Load Regulation                         : +/- 0.5 %
- Setup, Rise Time                        : 100 ms, 50 ms at full load
- Hold Up Time (Typ.)                 : 28 ms at full load

Input :
- Voltage Range                           : 88 - 132 VAC/176 - 264 VAC selectable by switch    248 - 370 VDC
- Frequency Range                       : 47 - 63 Hz
- Efficiency (Typ.)                        : 80 %
- AC Current (Typ.)                     : 3.2A/115 VAC    1.6A/230 VAC
- Inrush Current (Typ.)                 : Cold Start 35A
- Leakage Current                        : < 3.5 mA/240 VAC

Protection :
- Overload                                   : 105 - 150 % rated output power
                                                      Protection type : Shut down o/p voltage, re-power on to recover
- Over Voltage                             : 8.63 - 10.13 V
                                                      Protection type : Shut down o/p voltage, re-power on to recover

Environment :
- Working Humidity                      : 20 - 90 % RH non-condensing
- Working Temp.                          : -10 to +60 deg. C ( refer to output load derating curve )
- Storage Temp., Humidity            : -20 to +85 deg. C, 10 - 95 % RH
- Temp. Coefficient                       : +/- 0.03 % / deg. C ( 0 to 50 deg. C )
- Vibration                                    : 10 to 500 Hz, 2G 10 min / 1 cycle, period for 60 min, each along X,Y,Z axes

Safety & EMC ( Note 4 ) :
- Safety Standard                         : UL1012, UL60950-1, TUV EN60950-, CCC GB4943 approved
- Withstand Voltage                     : I/P-O/P : 3 KVAC  I/P-FG : 1.5 KVAC   O/P - FG : 0.5 KVAC
- Isolation Resistance                   :  I/P - O/P, I/P-FG, O/P-FG : 100 M Ohms / 500 VDC / 25 deg. C / 70 % RH
- EMI Conduction & Radiation    : Compliance to EN55022 (CISPR22) Class B
- Harmonic Current                      : Compliance to EN61000-3-2,-3
- EMS Immunity                          : Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light
                                                      industry level criteria A

Others :
- MTBF                                      : 286.7K hrs min. MIL-HDBK-217F (25 deg. C )
- Dimension                                 : 199 x 110 x 50 mm ( L x W x H )
- Packing                                     : 0.8 Kg

Note :
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient
    temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a
    0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment
    must be re-confirmed that it still meets EMC directives.
5. If the power supply is short-circuited under no load, it will recover automatically when short-circuit is removed.

PS-45 series

45 W Single Output Switching Power Supply

Features :

Universal AC input / full range
Low leakage current < 0.5 mA
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 65 KHz

Model : PS-45-7.5
Output :
- DC Voltage                                : 7.5 V
- Rated Current                             : 5.4 A
- Current Range                            : 0 - 7 A
- Rated Power                              : 40.5 W
- Output Power (max)                   : Rated output power for convection; 52W (+3.3V : 35W) with 18 CFM min.
- Ripple & Noise (max) Note 2     : 100 m Vp-p
- Voltage Adj. Range                    : 11.4 - 13.2 V
- Voltage Tolerance Note 3          : +/- 2.0 %
- Line Regulation                          : +/- 1.0 %
- Load Regulation                         : +/- 2.0 %
- Setup, Rise Time                        : 800 ms, 30 ms at full load
- Hold Up Time (Typ.)                 : 60 ms at full load

Input :
- Voltage Range                           : 90 - 264 VAC     127 - 370 VDC
- Frequency Range                       : 47 - 440 Hz
- Efficiency (Typ.)                        : 75 %
- AC Current (Typ.)                     : 0.8A/115 VAC    0.56A/230 VAC
- Inrush Current (Typ.)                 : Cold Start 15A/115 VAC        30A/230 VAC
- Leakage Current                        : < 0.75 mA/240 VAC

Protection :
- Overload                                   : 53 - 75 W ( 3.3V : 36 - 55 W ) rated output power
                                                      Protection type : Hiccup mode, recovers automatically after fault
                                                                                condition is removed.
- Over Voltage                             : 8.63 - 10.1 V
                                                      Protection type : Hiccup mode, recovers automatically after fault
                                                                                condition is removed.

Environment :
- Working Humidity                      : 20 - 90 % RH non-condensing
- Working Temp.                          : -10 to +60 deg. C ( refer to output load derating curve )
- Storage Temp., Humidity            : -20 to +85 deg. C, 10 - 95 % RH
- Temp. Coefficient                       : +/- 0.05 % / deg. C ( 0 to 50 deg. C )
- Vibration                                    : 10 to 500 Hz, 2G 10 min / 1 cycle, period for 60 min, each along X,Y,Z axes

Safety & EMC ( Note 4 ) :
- Safety Standard                         : UL60950-1, TUV EN60950-1 approved
- Withstand Voltage                     : I/P-O/P : 3 KVAC  I/P-FG : 1.5 KVAC   O/P - FG : 0.5 KVAC
- Isolation Resistance                   :  I/P - O/P, I/P-FG, O/P-FG : 100 M Ohms / 500 VDC 
- EMI Conduction & Radiation    : Compliance to EN55022 (CISPR22) Class B
- Harmonic Current                      : Compliance to EN61000-3-2,-3
- EMS Immunity                          : Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light
                                                      industry level  criteria A

Others :
- MTBF                                      : 300.7K hrs min. MIL-HDBK-217F (25 deg. C )
- Dimension                                 : 127 x 76 x 28 mm ( L x W x H )
- Packing                                     : 0.19 Kg

Note :  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient
    temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a
    0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment
    must be re-confirmed that it still meets EMC directives.
5. Mounting holes M1 and M2 should be grounded for EMI purposes