Model No. 5DGA04AS
Maker : Advance Power Solutions.
Specifications :-
Input : 90 to 250 VAC, 0.5A, 47 to 63 Hz
Output : 5.2V, 2A
12 V, 0.4A
- 12 V, 0.3A

Model : APS40ES Series
Maker : Advance Power Solutions.
Universal Input AC To DC External Deskstop Adaptor, Multiple Output
Switching Power Supplies 40 Watts
Features :-
- Automatically Accommodates Universal AC Sources
- Desktop Adaptor With IEC 320 Input Receptacle
- Designed To Meet Universal Safety Standards
- EMI / RFI Meet CISPR Pub. 22 Class B
- CE Marking Compliance
Input Specification :
- Input Voltage : Typical 90-265 VAC
- Input Connector : IEC 320 3P-AC receptacle
- Input Frequency : 47-63Hz (Consult factory for 440Hz operation)
- Inrush Current : 15A max. @ 230VAC
- Input Current : 1.0A @ 115VAC & 0.33A @ 30VAC
- Dielectric Withstand : (1*) Meets IEC 950
- EMI / RFI : Meets CISPR PUB. 22 class B
- Hold-up Time : 30mS typ. @ 115VAC, 120mS typ. @ 230VAC
Ouput Specification :
- Output Voltage : See Voltage / Current Ratings Charts Below
- Output Currents : See Voltage / Current Ratings Charts Below
- Output Connector : Optional
- Line Regulation : ±0.1% typical
- Load Regulation : (2*) ±3-5% depending on O/P cord
- Noise & Ripple : Typ. 1% peak to peak
- OVP : Built-in +5V O/P @ +6.4V ±0.4V, Option for other O/P @
124% typ.
- Adjustability : Factory set
- Overload Protection : 105% max. power
General Specifications :
- Efficiency : Typ. 75%
- Switching Frequency : About 37- 100 KHz
- Circuit Topology : Free-running flyback circuit
- Transient Response : Output voltage returns in less than 3mS
following a 50% load change
- Safety Standard : UL1950/EN60950
- Operating Temperature : 0 to 40°C
- Storage Temperature :-20 to +85°C
- Temperature Coefficient : 0.04% per °C
- Cooling : Free air convection
- Construction : Impact resistant thermo-plastic enclosure with venting
slot desktop format
Remarks : (1*) Dielectric Withstand : If at the cord strain
relief end for 1 minute, the results are 3,000VAC-Output/Input,
1,500VAC
- Input/GND, 500VAC - Output/GND
(2*) Load
regulation : The exact obtainable voltage regulation depends upon the
output cord selected and
load currents.
Upper data are for 6 ft.(2 meters) cord AWG #18/20 wires
with PF or PD type connector.
Voltage / Current Ratings
Chart.
Tripple Output.
Model No.
Main o/p vo1#
Aux. /p V02✝
Aux. /p VO3 $
Typ. Volt. Peak
Typ.
Volt.
Peak
Typ.
Volt.
Peak
APS40ES-30L3 5.0A +5V 6.0A
1.2A +12V 2.0A
0.25A -12V 1.0A
Symbols :" #" OVP built-in. "✝" Stacked on main output. "$"Installed
with Post Regulator(PR)
Remark : Peak output, less than 60 Sec., Peak current can't be drawn
from all output at the same time.
Weight : 570 g ( 20.1 Oz. )

S-4 0 series
40W Single Output Switching Power Supply
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 75KHz
Model : S-40-12
Output :
- DC Voltage
: 12 V
- Rated Current
: 3.5 A
- Current Range
: 0 - 3.5 A
- Rated Power
: 42 W
- Ripple & Noise (max) Note
2 : 100 m Vp-p
- Voltage Adj. Range
: 10.8 -
13.2 V
- Voltage Tolerance Note 3
: +/- 1.0 %
- Line Regulation
: +/- 0.5 %
- Load Regulation
:
+/- 0.5 %
- Setup, Rise Time
: 300 ms, 50 ms/230VAC 800 ms, 50 ms/115 VAC at full
load
- Hold Up Time (Typ.)
: 70 ms/230 VAC
15 ms/115 VAC at full load
Input :
- Voltage Range
: 85 - 264 VAC 120 - 370 VDC
- Frequency Range
: 47 -
63 Hz
- Efficiency (Typ.)
: 76%/ 115 VAC
- AC Current (Typ.)
:
1.2A/115 VAC 0.6A/230 VAC
- Inrush Current (Typ.)
: Cold Start 25A/115
VAC 50A/230 VAC
- Leakage Current
:
< 1 mA/240 VAC
Protection :
- Overload
: 105 - 150 % rated output power
Protection type : Hiccup mode, recovers automatically
after faulty
condition is removed
- Over Voltage
: 13.8 - 16.2 V
Protection type : Hiccup mode, recovers automatically
after faulty
condition is removed
Environment :
- Working Humidity
:
20 - 90 % RH non-condensing
- Working Temp.
: -10 to +60 deg. C ( refer to output load derating curve )
- Storage Temp., Humidity
: -20 to +85 deg. C, 10 - 96 %
RH
- Temp. Coefficient
:
+/- 0.03 % / deg. C ( 0 to 50 deg. C )
- Vibration
: 10 to 500 Hz, 2G 10 min / 1
cycle, period for 60 min, each along X,Y,Z axes
Safety & EMC ( Note 4 ) :
- Safety Standard
: UL1012, UL60950-1, TUV EN60950-1 approved
- Withstand Voltage
:
I/P-O/P : 3 KVAC I/P-FG : 1.5 KVAC O/P - FG : 0.5 KVAC
- Isolation Resistance
:
I/P - O/P, I/P-FG, O/P-FG : 100 M Ohms / 500 VDC
- EMI Conduction &
Radiation : Compliance to EN55022 (CISPR22) Class B
- Harmonic Current
:
Compliance to EN61000-3-2,-3
- EMS Immunity
: Compliance to EN61000-4-2,3,4,5;ENV50204, EN55024, light
industry
level criteria A
Others :
- MTBF
: 314.1K hrs min.
MIL-HDBK-217F (25 deg. C )
- Dimension
: 129 x 98 x 38 mm ( L x W x H )
- Packing
: 0.44 Kg
Note :
1. All parameters NOT specially mentioned are measured at
230VAC input, rated load and 25 of ambient
temperature.
2. Ripple & noise are
measured at 20MHz of bandwidth by using a 12" twisted pair-wire
terminated with a
0.1uf & 47uf
parallel capacitor.
3. Tolerance : includes set up
tolerance, line regulation and load regulation.
4. The power supply is
considered a component which will be installed into a final equipment.
The final equipment
must be
re-confirmed that it still meets EMC directives.
S-100F series
100W Single Output Switching Power Supply
Features :
AC input range selectable by switch
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 83 KHz
Model : S-100-7.5
Output :
- DC Voltage
: 7.5 V
- Rated Current
: 13.5 A
- Current Range
: 0 - 13.5 A
- Rated Power
: 101 W
- Ripple & Noise (max) Note
2 : 125m Vp-p
- Voltage Adj. Range
: 6.7 -
8.25 V
- Voltage Tolerance Note 3
: +/- 1.0 %
- Line Regulation
: +/- 0.5 %
- Load Regulation
:
+/- 0.5 %
- Setup, Rise Time
: 1000 ms, 30 ms at full load
- Hold Up Time (Typ.)
: 20 ms at full load
Input :
-Voltage Range
: 88 - 132 VAC/176 - 264 VAC selected by jumper or switch
248 - 370 VDC
- Frequency Range
: 47 -
63 Hz
- Efficiency (Typ.)
: 78 %
- AC Current (Typ.)
:
3.15A/115 VAC 1.5A/230 VAC
- Inrush Current (Typ.)
: Cold Start 20A/115
VAC 40A/230 VAC
- Leakage Current
:
< 1 mA/240 VAC
Protection :
- Overload
: 105 - 150 % rated output power
Protection type : Hiccup mode, recovers automatically after faulty
condition is removed
- Over Voltage
: 8.63 - 10.13 V
Protection type : Hiccup mode, recovers automatically after faulty
condition is removed
Environment :
- Working Humidity
:
20 - 90 % RH non-condensing
- Working Temp.
: -10 to +60 deg. C ( refer to output load derating curve )
- Storage Temp., Humidity
: -20 to +85 deg. C, 10 - 96 %
RH
- Temp. Coefficient
:
+/- 0.03 % / deg. C ( 0 to 50 deg. C )
- Vibration
: 10 to 500
Hz, 2G 10 min / 1 cycle, period for 60 min, each along X,Y,Z axes
Safety & EMC ( Note 4 ) :
- Safety Standard
: CSA60950-1 ( for 24V only ), UL1012, UL60950-1, TUV EN60950-1
CCC
GB4943 approved
- Withstand Voltage
:
I/P-O/P : 3 KVAC I/P-FG : 1.5 KVAC O/P - FG : 0.5 KVAC
- Isolation Resistance
:
I/P - O/P, I/P-FG, O/P-FG : 100 M Ohms / 500 VDC / 25 deg. C /
70% RH
- EMI Conduction &
Radiation : Compliance to EN55022 (CISPR22) Class B
- Harmonic Current
:
Compliance to EN61000-3-2,-3
- EMS Immunity
: Compliance to
EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level
criteria A
Others :
- MTBF
: 314.9K hrs min.
MIL-HDBK-217F (25 deg. C )
- Dimension
: 199 x 98 x 38 mm ( L x W x H )
- Packing
: 0.65 Kg
Note :
1. All parameters NOT specially mentioned are measured at
230VAC input, rated load and 25 of ambient
temperature.
2. Ripple & noise are
measured at 20MHz of bandwidth by
using a 12" twisted pair-wire terminated with a
0.1uf & 47uf
parallel capacitor.
3. Tolerance : includes set up
tolerance, line regulation and load regulation.
4. The power supply is
considered a component which will be
installed into a final equipment. The final equipment
must be
re-confirmed that it still meets EMC directives.
S-150 series
150 W Single Output Switching Power Supply
Features :
AC input range selectable by switch
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 25 KHz
Model : S-150-12
Output :
- DC Voltage
: 12 V
- Rated Current
: 12.5 A
- Current Range
: 0 - 12.5 A
- Rated Power
: 150 W
- Ripple & Noise (max) Note
2 : 180 m Vp-p
- Voltage Adj. Range
: 10.6 -
13.2 V
- Voltage Tolerance Note 3
: +/- 1.0 %
- Line Regulation
: +/- 0.3 %
- Load Regulation
:
+/- 0.3 %
- Setup, Rise Time
: 100 ms, 50 ms at full load
- Hold Up Time (Typ.)
: 28 ms at full load
Input :
- Voltage Range
: 88 - 132 VAC/176 - 264 VAC selectable by
switch 248 - 370 VDC
- Frequency Range
: 47 -
63 Hz
- Efficiency (Typ.)
: 82 %
- AC Current (Typ.)
:
3.2A/115 VAC 1.6A/230 VAC
- Inrush Current (Typ.)
: Cold Start 35A
- Leakage Current
:
< 3.5 mA/240 VAC
Protection :
- Overload
: 105 - 150 % rated output power
Protection type : Shut down o/p voltage, re-power on to recover
- Over Voltage
: 13.8 - 16.2 V
Protection type : Shut down o/p voltage, re-power on to recover
Environment :
- Working Humidity
:
20 - 90 % RH non-condensing
- Working Temp.
: -10 to +60 deg. C ( refer to output load derating curve )
- Storage Temp., Humidity
: -20 to +85 deg. C, 10 - 95 %
RH
- Temp. Coefficient
:
+/- 0.03 % / deg. C ( 0 to 50 deg. C )
- Vibration
: 10 to 500
Hz, 2G 10 min / 1 cycle, period for 60 min, each along X,Y,Z axes
Safety & EMC ( Note 4 ) :
- Safety Standard
: UL1012, UL60950-1, TUV EN60950-, CCC GB4943 approved
- Withstand Voltage
:
I/P-O/P : 3 KVAC I/P-FG : 1.5 KVAC O/P - FG : 0.5 KVAC
- Isolation Resistance
:
I/P - O/P, I/P-FG, O/P-FG : 100 M Ohms / 500 VDC / 25 deg. C / 70
% RH
- EMI Conduction &
Radiation : Compliance to EN55022 (CISPR22) Class B
- Harmonic Current
:
Compliance to EN61000-3-2,-3
- EMS Immunity
: Compliance to
EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light
industry level criteria A
Others :
- MTBF
: 286.7K hrs min.
MIL-HDBK-217F (25 deg. C )
- Dimension
: 199 x 110 x 50 mm ( L x W x H )
- Packing
: 0.8 Kg
Note :
1. All parameters NOT specially mentioned are measured at
230VAC input, rated load and 25 of ambient
temperature.
2. Ripple & noise are
measured at 20MHz of bandwidth by
using a 12" twisted pair-wire terminated with a
0.1uf & 47uf
parallel capacitor.
3. Tolerance : includes set up
tolerance, line regulation and load regulation.
4. The power supply is
considered a component which will be
installed into a final equipment. The final equipment
must be
re-confirmed that it still meets EMC directives.
5. If the power supply is
short-circuited under no load, it will recover automatically when
short-circuit is removed.
S-150 series
150 W Single Output Switching Power Supply
Features :
AC input range selectable by switch
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 25 KHz
Model : S-150-7.5
Output :
- DC Voltage
: 7.5 V
- Rated Current
: 20 A
- Current Range
: 0 - 20 A
- Rated Power
: 150 W
- Ripple & Noise (max) Note
2 : 150 m Vp-p
- Voltage Adj. Range
: 6
- 8.3 V
- Voltage Tolerance Note 3
: +/- 1.0 %
- Line Regulation
: +/- 0.5 %
- Load Regulation
:
+/- 0.5 %
- Setup, Rise Time
: 100 ms, 50 ms at full load
- Hold Up Time (Typ.)
: 28 ms at full load
Input :
- Voltage Range
: 88 - 132 VAC/176 - 264 VAC selectable by
switch 248 - 370 VDC
- Frequency Range
: 47 -
63 Hz
- Efficiency (Typ.)
: 80 %
- AC Current (Typ.)
:
3.2A/115 VAC 1.6A/230 VAC
- Inrush Current (Typ.)
: Cold Start 35A
- Leakage Current
:
< 3.5 mA/240 VAC
Protection :
- Overload
: 105 - 150 % rated output power
Protection type : Shut down o/p voltage, re-power on to recover
- Over Voltage
: 8.63 - 10.13 V
Protection type : Shut down o/p voltage, re-power on to recover
Environment :
- Working Humidity
:
20 - 90 % RH non-condensing
- Working Temp.
: -10 to +60 deg. C ( refer to output load derating curve )
- Storage Temp., Humidity
: -20 to +85 deg. C, 10 - 95 %
RH
- Temp. Coefficient
:
+/- 0.03 % / deg. C ( 0 to 50 deg. C )
- Vibration
: 10 to 500
Hz, 2G 10 min / 1 cycle, period for 60 min, each along X,Y,Z axes
Safety & EMC ( Note 4 ) :
- Safety Standard
: UL1012, UL60950-1, TUV EN60950-, CCC GB4943 approved
- Withstand Voltage
:
I/P-O/P : 3 KVAC I/P-FG : 1.5 KVAC O/P - FG : 0.5 KVAC
- Isolation Resistance
:
I/P - O/P, I/P-FG, O/P-FG : 100 M Ohms / 500 VDC / 25 deg. C / 70
% RH
- EMI Conduction &
Radiation : Compliance to EN55022 (CISPR22) Class B
- Harmonic Current
:
Compliance to EN61000-3-2,-3
- EMS Immunity
: Compliance to
EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light
industry level criteria A
Others :
- MTBF
: 286.7K hrs min.
MIL-HDBK-217F (25 deg. C )
- Dimension
: 199 x 110 x 50 mm ( L x W x H )
- Packing
: 0.8 Kg
Note :
1. All parameters NOT specially mentioned are measured at
230VAC input, rated load and 25 of ambient
temperature.
2. Ripple & noise are
measured at 20MHz of bandwidth by
using a 12" twisted pair-wire terminated with a
0.1uf & 47uf
parallel capacitor.
3. Tolerance : includes set up
tolerance, line regulation and load regulation.
4. The power supply is
considered a component which will be
installed into a final equipment. The final equipment
must be
re-confirmed that it still meets EMC directives.
5. If the power supply is
short-circuited under no load, it will recover automatically when
short-circuit is removed.
PS-45 series
45 W Single Output Switching Power Supply
Features :
Universal AC input / full range
Low leakage current < 0.5 mA
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 65 KHz
Model : PS-45-7.5
Output :
- DC Voltage
: 7.5 V
- Rated Current
: 5.4 A
- Current Range
: 0 - 7 A
- Rated Power
: 40.5 W
- Output Power (max)
: Rated output
power for convection; 52W (+3.3V : 35W) with 18 CFM min.
- Ripple & Noise (max) Note
2 : 100 m Vp-p
- Voltage Adj. Range
: 11.4 -
13.2 V
- Voltage Tolerance Note 3
: +/- 2.0 %
- Line Regulation
: +/- 1.0 %
- Load Regulation
:
+/- 2.0 %
- Setup, Rise Time
: 800 ms, 30 ms at full load
- Hold Up Time (Typ.)
: 60 ms at full load
Input :
- Voltage Range
: 90 - 264 VAC 127 - 370 VDC
- Frequency Range
: 47 -
440 Hz
- Efficiency (Typ.)
: 75 %
- AC Current (Typ.)
:
0.8A/115 VAC 0.56A/230 VAC
- Inrush Current (Typ.)
: Cold Start 15A/115
VAC 30A/230 VAC
- Leakage Current
:
< 0.75 mA/240 VAC
Protection :
- Overload
: 53 - 75 W ( 3.3V : 36 - 55 W ) rated
output power
Protection type : Hiccup mode, recovers automatically after fault
condition is removed.
- Over Voltage
: 8.63 - 10.1 V
Protection type : Hiccup mode, recovers automatically after fault
condition is removed.
Environment :
- Working Humidity
:
20 - 90 % RH non-condensing
- Working Temp.
: -10 to +60 deg. C ( refer to output load derating curve )
- Storage Temp., Humidity
: -20 to +85 deg. C, 10 - 95 %
RH
- Temp. Coefficient
:
+/- 0.05 % / deg. C ( 0 to 50 deg. C )
- Vibration
: 10 to 500
Hz, 2G 10 min / 1 cycle, period for 60 min, each along X,Y,Z axes
Safety & EMC ( Note 4 ) :
- Safety Standard
: UL60950-1, TUV EN60950-1 approved
- Withstand Voltage
:
I/P-O/P : 3 KVAC I/P-FG : 1.5 KVAC O/P - FG : 0.5 KVAC
- Isolation Resistance
:
I/P - O/P, I/P-FG, O/P-FG : 100 M Ohms / 500 VDC
- EMI Conduction &
Radiation : Compliance to EN55022 (CISPR22) Class B
- Harmonic Current
:
Compliance to EN61000-3-2,-3
- EMS Immunity
: Compliance to
EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light
industry level
criteria A
Others :
- MTBF
: 300.7K hrs min.
MIL-HDBK-217F (25 deg. C )
- Dimension
: 127 x 76 x 28 mm ( L x W x H )
- Packing
: 0.19 Kg
Note :
1. All parameters NOT specially mentioned are measured at
230VAC input, rated load and 25 of ambient
temperature.
2. Ripple & noise are
measured at 20MHz of bandwidth by
using a 12" twisted pair-wire terminated with a
0.1uf & 47uf
parallel capacitor.
3. Tolerance : includes set up
tolerance, line regulation and load regulation.
4. The power supply is
considered a component which will be
installed into a final equipment. The final equipment
must be
re-confirmed that it still meets EMC directives.
5. Mounting holes M1 and M2
should be grounded for EMI purposes