LIGHTNING SURGE PROTECTOR FOR POWER SUPPLY (2A)

                         Model : MA-200
   ( 2A, 200V/220V/240V AC line voltage use )

Functions & Features :-

• Designed specifically for AC power supplies up to 2 amps
• No degradation of normal (50/60 Hz) line frequency
• Power indicator lamp provided
  Specifications are subject to change without notice.

General Specifications :-

- Construction : Plug-inConnection: M3.5 screw terminals (chromated steel; torque 0.8 N·m)
- Housing materia l: Flame-resistant resin (black)
- Monitor lamp : Green neon lamp turns on when the power is supplied.

Installation :-

- Operating temperature: -5 to +55°C (23 to 131°F)
- Operating humidity: 30 to 90% RH (non-condensing)
- Mounting : Surface or DIN rail
- Dimensions : W50×H85×D119.5 mm (1.97”×3.35”×4.70”)
- Weight : 330 g (0.73 lbs)

Performance :-

                                           Between Lines           Line To Gnd
                                              
- Discharge voltage                  410V min.               410V min.
  (peak voltage)
- Max. surge voltage*              700V max.              700V max.
  (peak voltage)
- Leakage current                       ≤1mA                     ≤1mA
                                              @300V DC            @300V DC
- Rated line voltage                    200V AC                  ----
                                                 220V AC                  ----
                                                 240V AC                  ----
- Response time                                      ≤0.1 μsec.
- Discharge current                          1000A (8 / 20 μsec.)
- Max. load current                                       2A
- Voltage drop                                      ≤2V (50/60 Hz)

*The maximum voltage that could pass through the surge protector. Protected equipment must be able
   to withstand this voltage for a very short time period.

Standards & Approvals :-

- CE conformity: EMC Directive (2004/108/EC)
- EN 61000-6-4 (EMI)
- EN 61000-6-2 (EMS)
- Low Voltage Directive (2006/95/EC)
- EN 61010-1
- Installation category II
- Pollution degree 2
- Max. operating voltage 300V



            I/P Transducer  Model : VP-6-J

Functions & Features
• Converting a DC input into a proportional standard pneumatic signal
• Semiconductor pressure sensor in the feedback circuit
• High resolution
• No mounting position effect
• High-density mounting

Typical Applications
• Converting a 4 – 20mA from a PID controller into a pneumatic signal

Model             Input                                Power Input                               Options
                                                  AC Power            DC Power               • Output
  VP        A : 4 – 20mA DC       B : 100V AC        S : 12V DC      (blank): 0.2 – 1.0 kgf/cm2
               6 : 1 – 5V DC            C : 110V AC        R : 24V DC        /A1S : 19.6 – 98.1 kPa
                                                 D : 115V AC        V : 48V DC        /A2S : 20 – 100 kPa
                                                 F : 120V AC                                   /A3S : 20.7 – 103.4 kPa
                                                 G : 200V AC                                     /A2 : 0.2 – 1.0 bar
                                                 H : 220V AC                                     /A3 : 3 – 15 psig
                                                  J : 240V AC                        • Pneumatic Connection: Rc 1/4" standard
                                                                                                           /P7 : 1/4" NPT fitting

Input & Output :-
- Input :
   • DC Current: 4 – 20mA DC; shunt resistor attached to input terminals (0.5W)
     Input resistance: 250W

   • DC Voltage: 1 – 5V DC
     Input resistance: 1MW minimum

- Output : 19.6 – 98.1 kPa, 0.2 – 1.0 kgf/cm2
                20 – 100 kPa, 0.2 – 1.0 bar
                20.7 – 103.4 kPa, 3 – 15 psig

The output goes below 0% if the input loop is open.

- Maximum air delivery : 60 Nl/minute (2.1 SCFM)
- Maximum air exhaust : 60 Nl/minute (2.1 SCFM)

General Specifications :-
- Construction : plug-in
- Material : Housing: flame-resistant resin (black)
                  Base socket: die cast aluminium
                  Valve section: die cast aluminium
                  Screw terminals: nickel-plated steel; torque £0.8 N·m
- Connection : Input & power input: M3.5 screw terminals
                       Pneumatic: Rc 1/4" or 1/4" NPT female; torque £12 N·m
- Isolation : input to power
- Front adjustments : zero and span; ±5%
- Power input : AC : operational voltage range: rating ±10%, 50/60 ±2 Hz, approx. 2VA
                       DC : operational voltage range: rating ±10%, (ripple 10% p-p max.),
                                approx. 1W (30mA at 24V)
- Operating temperature : -5 to +60°C (23 to 140°F)
- Operating humidity : 30 to 90% RH (non-condensing)
- Mounting : surface
- Dimensions : W54´H101´D146.5 mm (2.13"´3.98"´5.77") excluding fitting and input resistor
- Weight : 750 g (1.65 lbs)

Installation :-
- Supply pressure: 140 kPa (1.4 kgf/cm2, 1.4 bar, 20 psig) ±10%
  Use dry air containing no carbon black or other foreign particles. To ensure reliability use an
   air filter (0.01 microns). Air consumption : 6 Nl / minute (0.21 SCFM)

Performance in percentage of span :-
- Accuracy : ±0.3% including linearity and repeatability
- Linearity : ±0.2%
- Repeatability : 0.1%
- Temp. coefficient : ±0.05%/°C (±0.03%/°F)
- Mounting position effect : ±0.1% (all dimensions)
- Response time : £3 seconds (0 – 90%)
- Line voltage effect : ±0.1% over voltage range
- Insulation resistance : ³100MW with 500V DC
- Dielectric strength : 2000V AC @1 minute (input to power to housing)


 
            P/I Transducer Model : PV-A-J

Functions & Features :-
• Converting a standard pneumatic signal into a proportional DC output • High-density mounting.

Typical Applications :-
• Converting a pneumatic system into a 4 – 20mA for indicating and controlling in DCS system

Model                             Output                                             Power Input                     Options
                  Current (DC)           Voltage (DC)             AC Power          DC Power           
   PV          A : 4 – 20mA           1 : 0 – 10mV           B : 100V AC        S : 12V DC    Pls refer ' *'         
                  B : 2 – 10mA           2 : 0 – 100mV         C : 110V AC        R : 24V DC    stated  below            
                  C : 1 – 5mA             3 : 0 – 1V                D : 115V AC       V : 48V DC               
                  D : 0 – 20mA           4 : 0 – 10V              F : 120V AC                                                  
                  E : 0 – 16mA            5 : 0 – 5V               G : 200V AC                                                    
                  F : 0 – 10mA            6 : 1 – 5V               H : 220V AC                                                    
                  G : 0 – 1mA          4W : -10 – +10V        J : 240V AC                                              
                  Z : Specify                0 : Specify                                                                                  
                       current                      voltage

' * ' :
• Input :
   (blank) : 0.2 – 1.0 kgf/cm2
   /A1S : 19.6 – 98.1 kPa
   /A2S : 20 – 100 kPa
   /A3S : 20.7 – 103.4 kPa
   /A2 : 0.2 – 1.0 bar
   /A3 : 3 – 15 psig
• Pneumatic Connection : Rc 1/4" standard
   /P7 : 1/4" NPT fitting

Input & Output :-

- Input : 19.6 – 98.1 kPa, 0.2 – 1.0 kgf/cm2
             20 – 100 kPa, 0.2 – 1.0 bar
             20.7 – 103.4 kPa, 3 – 15 psig

- Output :
   • DC Current : 0 – 20mA DC
     Minimum span : 1mA
     Zero suppression/elevation : max. 1.5 times span
     Load resistance : output drive 15V maximum

                     Output               Load Resistance
                   4 – 20mA            : 750 (W maximum)
                   2 – 10mA            : 1500
                   1 – 5mA              : 3000
                   0 – 20mA            : 750
                   0 – 16mA            : 900
                   0 – 10mA            : 1500
                   0 – 1mA              : 15k

   • DC Voltage : -10 – +12V DC
     Minimum span : 5mV
     Zero suppression/elevation : max. 1.5 times span
     Load resistance : output drive 10mA maximum;
                               5mA for negative voltage output; at ³0.5V

                     Output                Load Resistance
                   0 – 10mV             : 10k (W minimum)
                   0 – 100mV           : 100k
                   0 – 1V                  : 100
                   0 – 10V                : 1000
                   0 – 5V                  : 500
                   1 – 5V                  : 500
                 -10 – +10V            : 2000

General Specifications :-
- Construction : plug-in
- Material :
                 Housing: flame-resistant resin (black)
                 Base socket: die cast aluminium
                 Screw terminals: nickel-plated steel; torque £0.8 N·m
- Connection :
                     Output & power input: M3.5 screw terminals
                     Pneumatic: Rc 1/4" or 1/4" NPT female; torque £12 N·m
- Isolation : output to power
- Front adjustments : zero and span; ±5%

Installation
- Power input :
                       AC : operational voltage range: rating ±10%, 50/60 ±2 Hz, approx. 2VA
                       DC: operational voltage range: rating ±10% (ripple 10% p-p max.), approx.
                              2W (90mA at 24V)
- Operating temperature : -5 to +60°C (23 to 140°F)
- Operating humidity : 30 to 90% RH (non-condensing)
- Mounting : surface
- Dimensions : W54´H101´D138 mm (2.13"´3.98"´5.43") excluding fitting
- Weight : 550 g (1.21 lbs)

Performance in percentage of span
- Accuracy : ±0.3%
- Temp. coefficient : ±0.03%/°C (±0.02%/°F)
- Response time : <= 1.5 seconds (0 – 90%)
- Permissible overrange : 196 kPa (2.0 kgf/cm2, 1.96 bar, 28 psig)
- Line voltage effect : ±0.1% over voltage range
- Insulation resistance : >= 100MW with 500V DC
- Dielectric strength: 2000V AC @1 minute (output to power to housing)



      Differential RTD Transmitter Model : DR

Functions & Features :-
• Providing a DC output in proportion to the temperature difference between two RTDs
• Isolation up to 2000V AC
• Fast response type available
• LCD meter (engineering unit display selectable)
• Simple loop test output (0% and 100%)
• High-density mounting

Typical Applications :-
• Measuring temperature difference between the inlet and outlet of a heat exchanger
• Coolant
• Power plant (2000V AC isolation, 110V DC power supply)

Simple loop test output: 0% and 100% signal simulated by selecting the front switch positions.

Model                                         Output                                                Power Input                            Options
DR :                           Current                      Voltage                  AC Power            DC Power
Non-isolated       A : 4 – 20mA DC      1 : 0 – 10mV DC         B : 100V AC         S : 12V DC       Pls refer to below      
                           B : 2 – 10mA DC      2 : 0 – 100mV DC       C : 110V AC         R : 24V DC       mark ' * '   
                           C : 1 – 5mA DC        3 : 0 – 1V DC              D : 115V AC        V : 48V DC                     
                           D : 0 – 20mA DC      4 : 0 – 10V DC            F : 120V AC         P : 110V DC *1      
                           E : 0 – 16mA DC       5 : 0 – 5V DC             G : 200V AC                                        
                           F : 0 – 10mA DC       6 : 1 – 5V DC             H : 220V AC
                           G : 0 – 1mA DC         0 : Specify voltage        J : 240V AC
                           Z : Specify current

' * ' -
/E : LCD meter (0.0 – 100.0%)
/E2 : LCD display in engineering unit with backlight and the simple loop test output
/K : Fast response (DRS only) *1
*1 : Not selectable with Option/E2.

INPUT RTD (two)
- 2-wire RTDs; JPt 100 (JIS ’89) or Pt 100 (JIS ’97, DIN, IEC 751)
  Remark : Pt 100 (JIS ’89) is deviated from Pt 100 (JIS ’97) only within the described accuracy

Input & Output :-
■ Input : 2-wire RTDs (two)
   Maximum leadwire resistance : difference 0.5Ω maximum between the transmitter and each RTD; each
   leadwire resistance 10Ω or less
   Sensing current : 2mA
   Difference range : 0 – 20°C or 0 – 36°F (fixed)
   Temperature range : 0 – 50°C or 32 – 122°F (fixed)

■ Output
   • DC Current : 0 – 20mA DC
     Minimum span : 1mA
     Zero suppression/elevation : max. 1.5 times span
     Load resistance : output drive 15V maximum

        Output             Load Resistance
     4 – 20mA           : 750 (Ω maximum)
     2 – 10mA           : 1500
     1 – 5mA             : 3000
     0 – 20mA           : 750
     0 – 16mA           : 900
     0 – 10mA           : 1500
     0 – 1mA             : 15k

     • DC Voltage : -10 – +12V DC
       Minimum span : 5mV
       Zero suppression/elevation : max. 1.5 times span
       Load resistance : output drive 10mA maximum; 5mA for negative voltage output; at ≥0.5V

        Output              Load Resistance
     0 – 10mV            : 10k (Ω minimum)
     0 – 100mV          : 100k
     0 – 1V                 : 100
     0 – 10V               : 1000
     0 – 5V                 : 500
     1 – 5V                 : 500

General Specifications :-
- Construction : plug-in
- Connection : M3.5 screw terminals
- Housing material : flame-resistant resin (black)
- Isolation : input to output to power (non-isolated between I/O for DR)
- Overrange output : approx. -10 – +120% at 1 – 5V
- Front adjustments : zero and span; ±5%
- Display scaling : -10000 – +10000; ex-factory set to 0.00 – 100.00 (%)
- Engineering unit: %, μV, mV, V, mA, A, °C, °F, Ω or DEG K, mHz, Hz, kHz, VAC, AAC, mg, g, kg, t,
   rpm, rps selectable

Installation :-
- Power input :
     AC : operational voltage range: rating ±10%, 50/60 ±2 Hz, approx. 2VA (approx. 3VA with Option /E2)
     DC : operational voltage range: rating ±10%, or 85 – 150V for 110V rating ripple 10% p-p max. approx. 2W
              (80mA at 24V; approx. 3W with Option /E2)
- Operating temperature : -5 to +60°C (23 to 140°F)
- Operating humidity : 30 to 90% RH (non-condensing)
- Mounting : surface or DIN rail
- Dimensions : W50×H80×D127 mm (1.97"×3.15"×5") See General Spec. Sheet Figure A-1.
- Weight : 350 g (0.77 lbs)
- Terminal assignment : See General Spec. Sheet Figure B-1.

Performance in percentage of span :-
- Accuracy : ±0.2%*
- Display accuracy : ± (0.2% of FS + 1 digit)*
- Simple loop test output setting accuracy : ±0.5%
- Temp. coefficient : ±0.015%/°C (±0.008%/°F)
- Response time : ≤0.5 seconds (0 – 90%) approx. 25 milliseconds with option /K
- Line voltage effect : ±0.1% over voltage range
- Insulation resistance : ≥100MΩ with 500V DC
- Dielectric strength : 2000V AC @1 minute (DR: input or output to power to ground)
 *Temperature within 15 – 35°C or 59 – 95°F


 
              RTD Transmitter Model : RB

Functions & Features :-
• Accepting direct input from an RTD and providing a standard process signal
• Linearization
• Burnout protection
• "Active bridge" circuit containing two constant current sources allows large leadwire resistances up to 200Ω
• Isolation up to 2000V AC
• Fast response type available
• LCD meter (engineering unit display selectable)
• Simple loop test output (0% and 100%)
• High-density mounting

Typical Applications :-
• Long distance transmission between the RTD and the transmitter
• Combination with intrinsic safety barriers
• Power plant (2000V AC isolation, 110V DC power supply)

Model                          Input RTD                                   Output                                              Power Input                        Options
                                  ( 2 or 3 wire )               Current                      Voltage               AC Power           DC Power         Pls refer to ' * '
RB :                      1 : JPt 100 (JIS ’89)   A : 4 – 20mA DC      1 : 0 – 10mV DC     B : 100V AC     S : 12V DC            mark below
( Non-isolated )     3 : Pt 100 (JIS ’89)    B : 2 – 10mA DC      2 : 0 – 100mV DC   C : 110V AC     R : 24V DC
                             4 : Pt 100 (JIS ’97,     C : 1 – 5mA DC        3 : 0 – 1V DC         D : 115V AC     V : 48V DC
                                  DIN, IEC751 )      D : 0 – 20mA DC      4 : 0 – 10V DC       F : 120V AC      P : 110V DC *1
                             5 : Pt 50Ω (JIS ’81)    E : 0 – 16mA DC      5 : 0 – 5V DC         G : 200V AC
                             6 : Ni 508.4Ω             F : 0 – 10mA DC      6 : 1 – 5V DC          H : 220V AC
                             0 : Specify                  G : 0 – 1mA DC        0 : Specify voltage     J : 240V AC
                                                                Z : Specify current
 
' * ' :-
/E : LCD meter (0.0 – 100.0%)
/E2 : LCD display in engineering unit with backlight and the simple loop test output
/K : Fast response (RBS only) *1
/BL : Downscale burnout
/UL : UL approval *2
*1 : Not selectable with Option/E2.
*2 : Not selectable with Option/E or /E2.
100V/110V/115V/120V AC power only.

Input & Output :-
■ Input : 2- or 3-wire RTDs
   Maximum leadwire resistance : 200Ω per wire (3-wire)
   Sensing current : 2mA (Pt)
   Temperature range
 
              RTD                                           Usable Range                    Min. Span
                                                           °C                        °F             °C          °F
   JPt 100 (JIS ’89)                    -200 to +500      -328 to +932        50         90
   Pt 100 (JIS ’89)                      -200 to +650     -328 to +1202       50         90
   Pt 100 (JIS ’97/DIN/IEC)      -200 to +650      -328 to +1202       50         90
   Pt 50Ω (JIS ’81)                    -200 to +500       -328 to +932       100       180
   Ni 508.4Ω                               -50 to +200         -58 to +392        30         54

■ Output :
   • DC Current : 0 – 20mA DC
     Minimum span : 1mA
     Zero suppression/elevation : max. 1.5 times span
     Load resistance : output drive 15V maximum

      Output                          Load Resistance
    4 – 20mA                     : 750 (Ω maximum)
    2 – 10mA                     : 1500
    1 – 5mA                       : 3000
    0 – 20mA                     : 750
    0 – 16mA                     : 900
    0 – 10mA                     : 1500
    0 – 1mA                       : 15k

  • DC Voltage : -10 – +12V DC
    Minimum span : 5mV
    Zero suppression/elevation : max. 1.5 times span
    Load resistance : output drive 10mA maximum; 5mA for negative voltage output; at ≥0.5V

     Output                           Load Resistance
   0 – 10mV                      : 10k (Ω minimum)
   0 – 100mV                    : 100k
   0 – 1V                           : 100
   0 – 10V                         : 1000
   0 – 5V                           : 500
   1 – 5V                           : 500

General Specifications :-
- Construction : plug-in
- Connection : M3.5 screw terminals
- Housing material : flame-resistant resin (black)
- Isolation : input to output to power (non-isolated between I/O for RB)
- Overrange output : approx. -10 – +120% at 1 – 5V
- Front adjustments : zero and span; ±5%
- Display scaling : -10000 – +10000; ex-factory set to 0.00 – 100.00 (%)
- Engineering unit : %, μV, mV, V, mA, A, °C, °F, Ω or DEG K, mHz, Hz, kHz, VAC, AAC, mg, g, kg, t,
   rpm, rps selectable
- Simple loop test output: 0% and 100% signal simulated by selecting the front switch positions.
- Burnout protection : upscale standard; downscale optional
- Linearization : standard

Installation :-
- Power input :
    AC : operational voltage range: rating ±10%, 50/60 ±2 Hz, approx. 2VA (approx. 3VA with Option /E2)
    DC : operational voltage range: rating ±10%, or 85 – 150V for 110V rating ripple 10% p-p max. approx. 2W    
            (80mA at 24V; approx. 3W with Option /E2)
- Operating temperature : -5 to +60°C (23 to 140°F)
- Operating humidity : 30 to 90% RH (non-condensing)
- Mounting : surface or DIN rail
- Dimensions : W50×H80×D127 mm (1.97"×3.15"×5") See General Spec. Sheet Figure A-1.
- Weigh t: 350 g (0.77 lbs)
- Terminal assignment : See General Spec. Sheet Figure B-1.

Performance in percentage of span :-
- Accuracy : ±0.2%
- Display accuracy : ± (0.2% of FS + 1 digit)
- Simple loop test output setting accuracy : ±0.5%
- Temp. coefficient : ±0.015%/°C (±0.008%/°F)
- Response time : ≤0.5 seconds (0 – 90%) approx. 25 milliseconds with option /K
- Burnout response : ≤10 seconds
- Line voltage effect : ±0.1% over voltage range
- Insulation resistance : ≥100MΩ with 500V DC
- Dielectric strength : 2000V AC @1 minute (RB: input or output to power to ground)
                 
Standards & Approvals :-
- Approval : UL/C-UL general safety requirements (UL 3111-1, CAN/CSA-C22.2 No.1010-1)