Inmel 60 Calibrator, Multifunctional Meter - Calibrator For Automation Engineers

Parameters :-
1) Simulation And Measurement :
     - Thermocouple Signals J, K, T, R, S, B, U, L, E, N With Auto-Compensation Of Terminal Temperature.
     - Signals In Thermocouple And Thermostat System.
     - Resistance Thermometer Signals : Pt 100, Pt 500, Pt 1000, Ni 100, Cu 100.
     - Resistance Signals From 10 Ω To 5 KΩ
     - Voltages And Currents In Range : -11 V... +11 V, -22 mA...+22 mA.
2) Basic Error 0.025%.
3) STEP And RAMP Function.
4) Led Out 24 V Terminals.
5) RS232C Interface.
6) Available In The Option For Pressure Calibration.

Application :-
1) Checking And Calibration :
     - Measuring Transducers Controlled By A Voltage Or Current Signal, A Thermoelement Or Resistance Thermometer.
     - Two Wire Transducers.
     - Temperature Meters.
     - Pressure Transducers.
     - Manometers.
     - Measuring And Control Lines.

Technical Parameters :-

          Range                                                   Resolution                                    Basic Error (1)
                                                                                                     Measurement                        Generation

Voltage :
 -88 mV to 88 mV                                              1 uV              ± (0.05%  M + 4 d)             ± (0.05% S + 5 uV)
 -220 mV to 220 mV                                        10 uV             ± (0.025% M + 3 d)           ± (0.025% S + 30 uV)
 -2.2 V to 2.2 V                                              100 uV             ± (0.025% M + 2 d)          ± (0.025% S + 150 uV)     
 -11 V to 11 V (Measurement Up To 25V )       1 mV             ± (0.025% M + 2 d)          ± (0.025% S + 200 uV)

Current :
-22 mA to 22 mA                                               1 uA              ± (0.025% M + 3d)             ± (0.025% S + 3 uA)

Resistance :
10 Ω to 1000 Ω                                                0.1 Ωͧ              ± (0.05% M + 2 d ),             ± (0.05% S + 30 mΩ),
(Measurement From 0 Ω)                                                               Ip = 0.4 mA                           Ip = 10 mA
10 Ω to 5000 Ω                                                0.1 Ω              ± (0.05% M + 3 d ),           ± (0.05% S + 150 mΩ),
(Measurement From 0 Ω)                                                               Ip = 0.4 mA                            Ip = 1 mA       

Resistance Thermometer :
-200 to 850 ºC (Pt 100)                                   0.1 ºC            ± (0.025% M + 0.3 ºC)           ± (0.025% S + 0.1 ºC)
                                                                                                          Ip = 0.4 mA                          Ip = 10 mA      
-200 to 850 ºC (Pt 500, Pt 1000)                     0.1 ºC            ± (0.025% M + 0.3 ºC)           ± (0.025% S + 0.1 ºC)
                                                                                                          Ip = 0.4 mA                           Ip = 1 mA           
-50 to 180 ºC (Cu 100)                                    0.1 ºC            ± (0.025% M + 0.3 ºC)           ± (0.025% S + 0.1 ºC)
                                                                                                          Ip = 0.4 mA                           Ip = 10 mA           
-60 to 180 ºC (Ni 100)                                     0.1 ºC            ± (0.025% M + 0.3 ºC)           ± (0.025% S + 0.1 ºC)
                                                                                                          Ip = 0.4 mA                           Ip = 10 mA          

Thermocouple :
(J),   -210 to 1200 ºC (Fe-Cu Ni)                    0.1º C            ± (0.025% M + 0.5 ºC)           ± (0.025% S + 0.5 ºC)
(K), -270 to 1370 ºC (Ni Cr-Ni Al)                 0.1 ºC            ± (0.025% M + 0.5 ºC)           ± (0.025% S + 0.5 ºC)   
(T),  -270 to 400 ºC   (Cu-Cu Ni )                   0.1 ºC            ± (0.025% M + 0.5 ºC)          ± (0.025% S +  0.5 ºC)
(R),    -50 to 350 ºC   (Pt Rh 13-Pt)                 0.1 ºC            ± (0.05% M + 1.5 ºC)            ± (0.05% S +  1.5 ºC)
          350 to 1769 ºC (Pt Rh 13-Pt )               0.1 ºC            ± (0.05% M + 1 ºC)              ± (0.05% S +  1.0 ºC)
(S),   -50 to 0 ºC        (Pt Rh 10-Pt )                0.1 ºC            ± (0.05% M + 1.5 ºC)           ± (0.05% S +  1.5 ºC)   
            0 to 1769 ºC   (Pt Rh 10-Pt )               0.1 ºC            ± (0.05% M + 1 ºC)               ± (0.05% S +  1 ºC)
(B),  200 to 1820 ºC   (Pt Rh 30-Pt Rh6)         0.1 ºC            ± (0.025% M + 1 ºC)             ± (0.025% S +  1 ºC)
(U), -200 to 600 ºC    (Cu-Cu Ni )                  0.1 ºC            ± (0.025% M + 0.5 ºC)          ± (0.025% S +  0.5 ºC)
(L), -200 to 900 ºC     (Fe-Cu Ni )                   0.1 ºC            ± (0.025% M + 0.5 ºC)          ± (0.025% S +  0.5 ºC)
(E),   -50 to 700 ºC     (Ni Cr-Cu Ni )              0.1 ºC            ± (0.025% M + 0.5 ºC)          ± (0.025% S +  0.5 ºC)
(N), -270 to 1300 ºC  (Ni Cr Si Ni Si)             0.1 ºC             ± (0.025% M + 0.5 ºC)          ± (0.025% S +  0.5 ºC)

Pressure (2) :
-100 to 150 kPa                                                                                ± 0.1% M                               ± 0.1% S
0 to 7 MPa                                                                                        ± 0.1% M                               ± 0.1% S

Note : Ip = Measuring Current
           M = Measurement Value
           S = Setting Value
          (1) = During 12 Months After Calibration, At Temperature Of 23 ± 5 ºC
          (2) = Customer Establishes The Measuring Range Of The Pressure Transducer

General Technical Data :-
1) Power Supply : 230V ± 10%, 50 Hz, 15 VA
2) Battery / Power Consumption : 12V / 1.9 Ah / 4 VA Max.
3) Dimensions : 230 x 90 x 205 mm
4) Weight : 2.2 Kg
5) Operation Time : Min. 4 Hours
6) Battery Charging Time : 12 Hours
7) Accessories : Power Supply, Protective Carrier Bag, Measuring Wires
8) Working Temperature : +5... +40 ºC
9) Relative Humidity : 20...80%